EERIS
Engage in the European Research Infrastructures System
Browse the registry for
technological services
equipment
infrastructures
research
innovation
Login
Sign Up
MicroDERLab
University POLITEHNICA of Bucharest
Short link:
https://eeris.eu/
ERIF-2000-000Y-0883
1111
Visits
MicroDERLab is a Research Group at the University Politehnica of Bucharest, reuniting teams from the Faculty of Electrical Engineering, the Faculty of Power Engineering and The Faculty of Automatic Control and Computers. It promotes a common research agenda on electrical engineering themes focusing topics in power engineering while envisaging the intelligent networks of the future. Since 2013 MicroDERLab is full member of the European Distributed Energy Resources Laboratories e. V. (DERLab, ...
Mihaela
Albu
mihaela.albu@upb.ro
Professor
SCIENTIFIC TEAM
8
Mihaela ALBU
View profile
Sergiu AMBROSI
View profile
Mihai CALIN
View profile
Irina CIORNEI
View profile
Ana-Maria DUMITRESCU
View profile
Mihail POPA
View profile
Mihai SANDULEAC
View profile
Lucian TOMA
View profile
Energy Engineering Facilities (non-nuclear)
RI Domain of activity
Electrical and Optical Engineering Facilities
RI Domain of activity
Research Data Management Plan:
No information available
Access Policy to Research Infrastructure and Related Services:
No information available
Research Services
Studies on DC microgrids
SERVICE DESCRIPTION:
A DC flexible Microgrid is available for experiments in the MicroDERLab EB105 research laboratory. The rated voltage is 230 V, so that any appliance with switch mode power supply can be connected directly without the need of additional conversion.Several energy sources in the power range of 1 kW are available for testing the microgrid operation: a PV system; fuel cell; a variable DC power supply, a 250 Ah storage unit and a Triphase TM Rapid Prototyping Platform (5kVA) which can be used either as a power generator or a power electronics converter module. Additionally several power electronics converters are available for flexible configuration of the energy flow control. Lightning in the laboratory is partially supplied from the DC ring. Other loads (including the computers) can be directly connected through custom-designed plug-in boxes. Grid operation can be monitored and controlled from a central control unit (PC) via Ethernet.
SERVICE PERSONS:
Mihaela ALBU
View profile
Irina CIORNEI
View profile
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Studies on synchronized measurements
SERVICE DESCRIPTION:
The mobile Synchronized Measurements laboratory is composed of 6 mobile PMU racks and a datacenter. Five racks are equipped with single channel (three currents and three voltages) 1133 Power Sentinel PMUs, and one rack is equipped with SEL 487E multichannel PMU provided with 18 current inputs (6 three-phase current channels) and 6 voltage (2 three-phase independent channels) inputs. All racks have installed a communication module enabling connections to the datacenter in Bucharest via broadband 3G modems. Datacenter consists of one PDC based on the open PDC platform and one server capable of running several applications for PMU data analyzers and processing for example parameter identification and data mining. The PMUs are usually deployed within the distribution networks of Romanian DSOs.
SERVICE PERSONS:
Mihaela ALBU
View profile
Mihail POPA
View profile
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Studies on power system emulator
SERVICE DESCRIPTION:
A laboratory power system model consisting of one substation, one synchronous generator and grid synchronization module, transmission line, transformers and R-L variable loads is successfully used at UPB (Room EI-210) to study a large number of applications and events specific to real power systems. The model is completed with a wind generator of which operation in terms of wind speed and power output is monitored in real time; a lead acid battery is used to store the energy produced by wind generator, then to supply several variable loads. Various system configurations using the individual elements can be obtained to study either transmission system or distribution system operation issues. The model is flexible and allows testing algorithms and procedures like PMUs-based network parameters identification, protection for active distribution networks and grid-connected DG operation.
SERVICE PERSONS:
Lucian TOMA
View profile
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Studies on rapid prototyping platform
SERVICE DESCRIPTION:
The Rapid Prototyping platform has hardware and software building blocks allowing implementation and test of new equipment ideas and control strategies in the following areas: • Power amplifiers and waveform generators • Programmable voltage and current sources • Motor drives • Active filters • Microgrids. One unit (5 kVA) is installed in UPB - the EB105 room. A second unit (90kVA) is connected to a real distribution grid (Cheia substation, 160 km North of Bucharest), can be operated remotely and is used in collaboration with one of the Romanian DSOs. Both platforms are programmed and controlled in real time with Matlab/Simulink™. All parameters and process values are available for being changed and monitored directly from the numerical simulation environment.
SERVICE PERSONS:
Sergiu AMBROSI
View profile
Mihai CALIN
View profile
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Smart metering consultancy
SERVICE DESCRIPTION:
MicroDERLab can offer consultancy for the development, deployment and usage of smart meters. The expertise is proven by the involvement of the team members in international projects (IEE SmartRegions an H2020 Flexmeter) and the work on the Romanian Electricity Metering Code (ANRE).
SERVICE PERSONS:
Ana-Maria DUMITRESCU
View profile
Mihai SANDULEAC
View profile
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Power quality consultancy
SERVICE DESCRIPTION:
MicroDERLab can offer consultancy in the field of power quality. The expertise is proven by the involvement of the team members in international (FP6 VSyNC, FP6 CRISTAL) and national (ActiveDGModel) projects and the work on the technical committees of the Romanian Standardisation Association (ASRO).
SERVICE PERSONS:
Mihaela ALBU
View profile
Ana-Maria DUMITRESCU
View profile
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Research Equipment
SEL-487E-3, -4 Relay
CATALOG NAME:
SEL-487E Transformer Differential Relay
DESCRIPTION:
The SEL-487E Relay, provides a suite of current andvoltage elements for the comprehensive protection of two-winding, threewinding, four-winding, and five-winding power transformers. In total, the relay consists of 24 analog channels, divided into three groups of analog inputs. The first group consists of 15 channels for phase current inputs, the second group consists of 3 channels for single-phase (neutral) current inputs, and the third group consists of 6 channels for two three-phase voltage inputs.
PRODUCER:
SCHWEITZER ENGINEERING LABORATORIES, INC.
PRODUCTION YEAR:
2012
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Download data sheet file (319.84 kb)
PQube3
CATALOG NAME:
PQube3
DESCRIPTION:
PQube® 3 is an instrument for monitoring electric power systems and is a combination of a power disturbance monitor, a power meter, a power recorder, and a digital camera. It records disturbances on the mains circuit: sags/dips, swells, interruptions, frequency variations, and disturbances on two analog input channels. It also records impulses, waveform snapshots, unbalance, flicker, and THD, and trend data. When equipped with compatible current transformers, PQube 3 also records current waveforms. It records all data on internal memory plus a removable microSD card, which can be read by any computer. No special software is and it can be configured with the free PQube Configurator program.
PRODUCER:
PSL, Power Sensors Limited
PRODUCTION YEAR:
2015
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Download data sheet file (137.15 kb)
Triphase 5kVA
CATALOG NAME:
Rapid Prototyping Platform Triphase 5kVA
DESCRIPTION:
5kVA bidirectional Power Module with 6-channel output that can be used in various AC and DC configurations. Suited for bidirectional energy flow between the supply grid and single phase AC, three phase AC or DC loads and sources. The power module contains all necessary voltage, current and temperature measurements, configuration and connection contactors and safety features such as emergency stop, protection against overcurrent, overvoltage and overtemperature, fuses, covers on high-voltage parts and a door sensor.
PRODUCER:
Triphase NV
PRODUCTION YEAR:
2008
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Download data sheet file (51.07 kb)
1133A Power Sentinel PMUs
CATALOG NAME:
Arbiter Systems®, Inc. Model 1133A Power Sentinel™
DESCRIPTION:
4 Arbiter PMUs connected by the PDC system. The Arbiter PMU is a leader in synchrophasor measurement and analysis, and the 1133A model merges precision time synchronization and power measurement features into a single PMU compatible device, as you can see in the picture above. 1133A is a rack mountable Phasor Measuremtn Unit compatible device featuring the highest accuracy posible. It measures system phase angle, monitor power quality, derive frequency and time deviations and tackle revenue metering challenges from a single unit.
PRODUCER:
Arbiter Systems®, Inc.
PRODUCTION YEAR:
2010
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Download data sheet file (2735.7 kb)
Data concentrator
CATALOG NAME:
Data server with application based on OpenPDC
DESCRIPTION:
The PDC functions like a data aggregator with time aligment. The OpenPDC application runs on a Windows virtual machine installed on a High Performance Server. It allows the storage and offline retrival of data from the 5 PMUs (4 Arbiter and 1 SEL) available in the laboratory. The downloadable files (using the online platform) are in CSV format.
PRODUCER:
application based on OpenPDC (open source)
PRODUCTION YEAR:
2012
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Phone:
+ 4021-402 9740
Fax:
+4021-4029342
Splaiul Independentei
,
313
,
Bucuresti
060042
,
Bucuresti - Sector 6
Romania
Loading Infrastructure
[T: 0.6662, O: 329]
Notification!
EERTIS
has replaced eeris. From now on, all updates and account activities will be on
EERTIS
. However, you can still migrate your remaining data from eeris to
EERTIS
.