ERRIS
Engage in the Romanian Research Infrastructures System
 
Boltzman
Last Update: 31.12.2014
Infrastructure direct public link in ERRIS:
VISITS
REVIEW(S)
SCIENTIFIC & TECHNICAL TEAM:
err
Coordinator:

CONTACT:
Phone:
Fax:
Zip code:
Address: , ,
,
RESEARCH SERVICES:
•  Synthesis of nanomaterials by hydrothermal and microwave-hydrothermal methods.
•  Electrical properties measurements under controlled atmosphere (vacuum) and at high temperatures up to 1200ºC
•  Thermal analysis: TG-DSC.
•  Thermal behaviours.
•  Measurements of heat content (Enthalpy), specific heats (Cp), heats of formation of complex oxides and alloys.
•  Thermomecanical analysis (TMA).
•  FTIR (diamond ATR) technique.
•  BET (Brunauer-Emmett-Teller) method.
•  Measurements by using combustion calorimetry .
•  Measurements of melting /decomposition temperatures, the enthalpies of transformation and heat capacities
•  Measurements by isothermal titration calorimetric (ITC).
•  Measurements by differential scanning calorimetry (NanoDSC).
•  Measurements of heat of dissolution by calorimetry using C80 Calvet calorimeter.
•  Vapor pressure and phase diagrams (vapor-liquid) measurements at low and moderate pressures by dynamic method
•  Measurements of density and sound velocity for pure compounds and liquid mixtures.
•  Measurements of refractive index for pure compounds and liquid mixtures.
•  Measurements of viscosity for pure compounds and liquid mixtures.
•  Measurements of cell potential with ion-selective electrodes (ISE) for liquid mixtures.
•  Measurements of zeta potential for liquid mixtures.
•  UV-VIS spectrocopy.
•  Measurements of liquid-liquid equilibrium.
•  Measurements of the surface, interfacial tension, critical micelle, concentration, contact angle on solids, fibers and powders
•  Development of electrochemical sensing platform for the detection of biomolecules (i.e. proteins).
•  Thermodynamic properties by electromotive force measurements (EMF) on solid electrolyte galvanic cell.
•  Electrical properties measurements under controlled atmosphere (vacuum) and at high temperature up to 1200 grd
•  Electromotive force measurements (EMF) on solid electrolyte galvanic cells.
EQUIPMENTS:
•  High pressure reactor with temperature and presure control Berghof BR100
•  Microwave reactor Berghof SpeedWave2
•  1255A Frequency Response Analyzer
•  Agilent HP 4285 LCR Meter
•  Solartron 1287 Potentiostat/Galvanostat
•  ProboStat ECs
•  TMA Setsys Evolution 17 calorimeter
•  Spectrophotometer FTIR NICOLET IS10, Thermo Scientific.
•  Equipement for Surface characterization of materials. BET (Brunauer-Emmett-Teller) method. Nova 2200e, Quantachrome.
•  Clarus 600 gas chromatograph with FID and TCD detectors
•  Equipement for Measuremets of the of density and sound velocity for pure compounds and liquid mixtures: DSA 5000M - Density and Sound Velocity Meter, Anton Paar
•  Spectrophotometer with thermostating Cary bio 300 UV-VIS .
•  Calorimeter Calvet C80
•  Calorimeter - Drop Calorimeter Setaram MHTC96.
•  Microcalorimeter MicroCal iTC200
•  Equipement for Measuremets of the vapor-liquid equilibrium, Fischer Labodest 602/D
•  Keithley multimeter 2000
•  Active Pirani Gauge
• 
•  Equipement for Measuremets of the thermodynamic properties by Electromotive force measurements (EMF) on solid electrolyte galvanic cell under controlled atmosphere (vacuum) and at high temperature up to 1200grd : Keithley Multimeter 2000, Vacuum equipment, Active Pirani Gauge, Active Inverted Magnetron Gauge, Active Gauge Controller, Edwards High Vacuum
•  Equipement for Measuremets of the Development of electrochemical sensing platform for the detection of biomolecules (i.e. proteins)
•  Equipement for Measuremets for surface energy measurements with Kruss K100 Tensiometer
•  Equipement for Measuremets of the liquid-liquid equilibrium.
•  Zetasizer NanoZS, Malvern Instruments (UK).
•  Automated Microviscometer AMVn Anton Paar.
•  Refractometer Anton Paar ABBEMAT RXA 170 digital.
•  Equipement for Measuremets of Vapor pressure and phase diagrams (vapor-liquid) measurements at low and moderate pressures by dynamic method.
•  Calorimeter Nano DSC 3600A , TA Instruments
•  Calorimeter DSC 8500 , Perkin Elmer.
•  Calorimeter 6200 , Parr Instruments
•  Calorimeter TMA Setsys Evolution 17, Setaram.
•  Calorimeter DSC-TG Setsys Evolution 17, Setaram.
•  Equipement for Measuremets of the Electrical properties measurements under controlled atmosphere (vacuum) and at high temperatures up to 1200ºC : 1255A Frequency Response Analyzer Solartron; HP4285A LCR meter Agilent; 1287 Potentiostat/Galvanostat Solartron; ProboStat™ cell NorECs, TSV/12/45/300-2216 Furnance Elite, software (ZPlot; ZView;CorrWare;CorrView ).
•  Equipement for Measuremets of Synthesis of nanomaterials by hydrothermal and microwave-hydrothermal methods :High pressure reactor with temperature and pressure control Berghof BR100 Microwave reactor Berghof SpeedWave2.
REVIEWS:

Latest Reviews


[T: 0.8396, O: 772]