EERIS
Engage in the European Research Infrastructures System
Browse the registry for
technological services
equipment
infrastructures
research
innovation
Login
Sign Up
LABORATORY FOR PHYSICO-CHEMICAL CHARACTERIZATION AND CONFORMITY ASSESSMENT FERTILIZERS, SOIL AMENDMENTS AND SOIL IMPROVERS.
National Research and Development Institute for Chemistry and Petrochemistry-ICECHIM
Short link:
https://eeris.eu/
ERIF-2000-000W-0763
706
Visits
ICECHIM Analysis Laboratory is an specialized team that performs analytical research studies and also services accredited by RENAR in conformity with SR EN 17025 (LI 843/23.01.2014). The main areas of competence are: environmental quality monitoring (air, water and wastes) and control of products conformity (fertilizers and biocides). Laboratories are equipped with modern equipment for specific methods of analysis and performs physico-chemical analysis of materials in different matrices: - ...
Mihaela
MANOLACHE
dir.calitate@icechim.ro
Dr. Ing.
SCIENTIFIC TEAM
1
Luiza CAPRA
View profile
Analytical Facilities
RI Domain of activity
Agronomy, Forestry, Plant Breeding Centres
RI Domain of activity
Research Data Management Plan:
No information available
Access Policy to Research Infrastructure and Related Services:
No information available
Research Services
LABORATORY TESTS FOR FERTILIZERS AND BIOCIDES
SERVICE DESCRIPTION:
LABORATORY TESTS FOR FERTILIZERS AND BIOCIDES Providing services Consulting and training - Other services International recognized for services conformity control of fertilizers. - RENAR accredited laboratory according with SR EN ISO/IEC 17025:2005 - Laboratory recognized internationally as being notified to the European Commission approved laboratory in Romania (according to Ord. No. 458/2008 of the Minister of Agriculture and Rural Development), competent control services to ensure compliance fertilizers; - Potential for development and accreditation of new analytical methods, depending on market requirements. - The laboratory is notified at European level because of competence provide the necessary services for checking compliance of EC fertilizers with the requirements of Regulation (EC) No 2003/2003; - By participating in the Scheme comparisons between laboratories PTS-24 "Mineral fertilizers", organized by Bipea - France, National Research and Development Institute for Chemical and Petrochemical became a member of Bipea; - Analytical procedures for determining nutrient is carried out in accordance with the methods described in Annex IV B - Regulation (EC) No 2003/2003; - The laboratory is equipped with modern equipment and is able to analyze a large number of samples daily; - The laboratory is able to quantify residual fertilizer in different matrices (eg soil, water, soil amendments, soil improvers, etc).
SERVICE PERSONS:
Luiza CAPRA
View profile
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Accredited procedures.
SERVICE DESCRIPTION:
- Ammonia Nitrogen Determination according to Regulation EC No. 2003/2003, Annex IV B, Method 2.1; - Determination of nitrate nitrogen and ammonia after Ulsch according to Regulation EC No. 2003/2003, Annex IV B, Method 2.2.1; - Determination of total nitrogen in urea according to Regulation EC No. 2003/2003, Annex IV B, Method 2.3.3; - Extraction of phosphorus soluble in mineral acids / CAN / water according to Regulation EC No. 2003/2003, Annex IV B, Method 3.1.1 / 3.1.4 / 3.1.6; - Determination of extracted phosphorus (gravimetric method) according to Regulation EC No. 2003/2003, Annex IV B, Method 3.2; - Determination of water-soluble potassium according to Regulation EC No. 2003/2003, Annex IV B, Method 4.1; Laboratory Equipment: - Optima 2100 DV ICP-OES System; - Multiwave 3000 (Microwave Sample Preparation System (Anton Paar); - Device determination of water content 831 Karl-Fischer Coulometer METRHOM; - TitroLine alpha plus (Schott).
SERVICE PERSONS:
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Research Equipment
Optima 2100 DV ICP-OES System
CATALOG NAME:
DESCRIPTION:
Mesurement range: ppb – ppm - %w/w Analytes: metals Matrices: water, fertilizer Operation and Data processing software: WinLab 32 Other relevant characteristics: - system includes complete dual-viewing optics under computer & software control - backside – illuminated CCD array detector with two photosensitive segments containing 176 by 128 pixels Double spectrometer optical system Spectral range: 160-900 nm with resolution of 0.009 nm @ 200 nm RF generator power: 40 MHz
PRODUCER:
Perkin Elmer
PRODUCTION YEAR:
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Multiwave 3000 (Microwave Sample Preparation System (Anton Paar)
CATALOG NAME:
DESCRIPTION:
microwave power: 1200 W temperature range: 100 – 300 °C maximum pressure: 120 bar position rotor with PTFE-TEM vessels: 8
PRODUCER:
PRODUCTION YEAR:
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Device determination of water content 831 Karl-Fischer Coulometer METRHOM
CATALOG NAME:
DESCRIPTION:
used for coulometer water content determination in solid, liquid & gaseous samples water content measurement range: 10μg -200mg H2O number of user methods: 50 predefined Mettler methods: 5
PRODUCER:
METRHOM
PRODUCTION YEAR:
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
TitroLine alpha plus (Schott)
CATALOG NAME:
DESCRIPTION:
data base for 100 methods pH – measuring titration of strong acids & alkaline solutions titrations in aqueous in non – aqueous systems
PRODUCER:
PRODUCTION YEAR:
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Phone:
+4021-315.32.99
Fax:
+4021-312.34.93
Spaiul Independentei
,
202
,
Bucharest
060021
,
Bucuresti - Sector 6
Romania
Loading Infrastructure
[T: 0.4655, O: 195]
Notification!
EERTIS
has replaced eeris. From now on, all updates and account activities will be on
EERTIS
. However, you can still migrate your remaining data from eeris to
EERTIS
.