EERIS
Engage in the European Research Infrastructures System
Browse the registry for
technological services
equipment
infrastructures
research
innovation
Login
Sign Up
CAMPUS - Lab22 - UPB
University POLITEHNICA of Bucharest
Short link:
https://eeris.eu/
ERIF-2000-000X-2674
467
Visits
Circulating fluidized bed combustion with CO2 capture by chemical absorption process; Polymeric membrane pilot installation for separate CO2 from pre- and post-combustion process
Cristian
Dinca
cristian.dinca@upb.ro
Dr
Energy Engineering Facilities (non-nuclear)
RI Domain of activity
Mechanical Engineering Facilities
RI Domain of activity
Pilot Plants for Process Testing
RI Domain of activity
CO2 capture technologies/Gas separation
RI Domain of activity
Research Data Management Plan:
No information available
Access Policy to Research Infrastructure and Related Services:
No information available
Research Services
Testing organic and inorganic membranes for gas separation
SERVICE DESCRIPTION:
Separation of CO2 from the flue gasses generated by the fossil fuels or biomass combustion. In order to avoid the dust and acid gases (other then CO2), the combustion process is simulated using gases tank.
SERVICE PERSONS:
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Physical-chemical absorption
SERVICE DESCRIPTION:
Research work and services using physical-chemical absorption processes for the absorption capacity determination according to the chemical or physical solvent used. The results are determined by experimental or modelling and simulation study.
SERVICE PERSONS:
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Air pollution assessment
SERVICE DESCRIPTION:
Modelling and experimental research to develop/implement analytical methods/techniques for air pollution evaluation (emission/imission) and to assess the industrial activities impact on air quality (dispersion modelling, noise maps, greenhouse gases) and also, services of air pollution monitoring.
SERVICE PERSONS:
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Training and research on environmental monitoring and impact assessment
SERVICE DESCRIPTION:
Training by special modules within the framework of Doctoral School (PhD students) and research activities in environmental monitoring and impact assessment.
SERVICE PERSONS:
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Environmental analysis of industrial processes
SERVICE DESCRIPTION:
Development of techniques and methodologies for environmental analysis (life-cycle assessment, carbon footprint, energy and water consumption minimization) of industrial activities.
SERVICE PERSONS:
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Optimization of Industrial Chemical Processes
SERVICE DESCRIPTION:
Modeling, simulation and optimization of chemical processes using engineering software (Matlab, Hysys, Aspen Plus, Aspen Custom Modeler, IPSE Pro & MDK, Chemcad etc.).
SERVICE PERSONS:
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Thermo gravimetric characterization of materials
SERVICE DESCRIPTION:
HGIM/Thermo gravimetric characterization of biomass and waste used in gasification processes usig STA/DSC/TGA system
SERVICE PERSONS:
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Environmental measurements on directed emission /emissions from stationary sources and on immision/atmospheric air
SERVICE DESCRIPTION:
Measurement of flue gas composition on directed emission /emissions from stationary sources.
SERVICE PERSONS:
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Research Equipment
Membrane tester pilot plant
CATALOG NAME:
DESCRIPTION:
Used for determining the performances of the polymeric and ceramic membranes in terms of CO2 absorption.
PRODUCER:
PRODUCTION YEAR:
2015
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
GC-MS
CATALOG NAME:
DESCRIPTION:
It used for determining the gas compositions. HGIM/The 8610C can control up to 16 heated zones, three gas sampling valves, and seven EPC gas pressures. Up to six detectors, from a choice of 16, can be mounted simultaneously. The 8610C shown below is equipped with five detectors. The 8610C column oven is temperature programmable from ambient to 400°C with unlimited ramps andholds, and fast cool-down. This airbath oven can hold a standard 7-inch diameter megabore column cage, or multiple columns with smaller coil sizes. The 8610C can be configured to implement virtually any EPA or ASTM method while remaining small enough to ship via FedEx and UPS, or even check as checked airline baggage.
PRODUCER:
PRODUCTION YEAR:
2015
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Spectrometer ICP-OES Perkin Elmer Optima 5300 DV / 077C8040903
CATALOG NAME:
Perkin Elmer Optima 5300 DV ICP-EOS
DESCRIPTION:
The Optima 5300 DV ICP-OES offers the performance required to maximize productivity. Its optimized design allows for accuracy, improved method development, and consistency. The system is ideal for laboratories with moderate to heavy loads of difficult samples. The equipment use WinLab32 instrument control and data management software. The equipment allows simultaneous determination of metals, axial and radial viewing of the plasma. The sample introduction system could be classic (Meinhard nebulizer) or with an USN 6000AT+ CETAC for ultra-trace elements. Equipped with a FIAS 400 Flow Injection System for volatile metals.
PRODUCER:
Perkin Elmer
PRODUCTION YEAR:
2008
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
UV-VIS spetrometer
CATALOG NAME:
Lambda 25
DESCRIPTION:
Wavelength Range: 190–1100 nm; Bandwidth: 1 nm, Wavelength; Absorbance.
PRODUCER:
Perkin Elmer
PRODUCTION YEAR:
2006
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
FTIR spetrometer
CATALOG NAME:
Spectrum BXII
DESCRIPTION:
Optical system covering the range 7800 – 350 cm-1; resolution.
PRODUCER:
Perkin Elmer
PRODUCTION YEAR:
2006
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
TOC-analyzer
CATALOG NAME:
Apollo 9000
DESCRIPTION:
Range*: 4 ppb to 4,000 ppm (sample volume and dilution dependent) using only 4 selectable analytical ranges; Precision*: Typical 0.25% of full scale or.
PRODUCER:
Teledyne Tekmar
PRODUCTION YEAR:
2005
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Circulated Fluidized bed combustion pilot installation
CATALOG NAME:
DESCRIPTION:
Testing the lignite/biomass combustion; CO2 capture post-combustion by chemical absorption process; desulphurization unit using NaOH 1 wt.%; optimization and integration process.
PRODUCER:
PRODUCTION YEAR:
2007
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Flue gas analyser
CATALOG NAME:
Testo 350-S Control Unit in combination with Testo 350-S/-XL Flue Gas Analyzer
DESCRIPTION:
Test up to six gases simultaneously, or swap sensors out: O2 , CO, CO low, NO, NO low, NO2 , SO2 , H2 S, CO2 (NIDIR), CH (total hydrocarbons) • Dilution system (optional) for the widest testing ranges and greatest sensor protection: (CO to 400,000 ppm) (NO, NO2 , SO2 , H2 S to fi ve times the sensor range) • Advanced sample conditioning utilizes a thermoelectric chiller for moisture drop-out and a peristaltic hose pump for controlled water removal and EPA compliance • Automatic fl ow-controlled pump with high strength sampling to over 50 feet away • Proven sample gas path with Tefl on® lined hoses • Continuous temperature compensation for assured accuracy • User defi ned automated testing programs with onboard memory to 250,000 values • Integrated pressure measurement for draft, P, velocity, fl ow and mass emissions calculations (with Pitot tube) • Display refresh rate at one second intervals • Measurement averages can be shown on display • AC and rechargeable battery operation with optional DC connection operation.
PRODUCER:
TESTO
PRODUCTION YEAR:
2014
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Portlable emission analyser TESTO 335
CATALOG NAME:
TESTO 335
DESCRIPTION:
TESTO 335 is the flue gas analyser of the new generation, specially tailored to the requirements of industrial applications. It is equipped with an O2 measuring cell as standard. Two additional toxic measuring cells such as CO and NO, are fitted by the user as required. This guarantees highest flexibility when adapting to changing applications or measurement jobs. Due to the fact that adjustment data is stored in the measuring cell, it can be changed quickly and easily by the user .
PRODUCER:
TESTO
PRODUCTION YEAR:
2009
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Thermogravimetric analyzer
CATALOG NAME:
PERSEUS® STA 449 F1/F3 Jupiter®
DESCRIPTION:
HGIM/The PERSEUS® STA 449 F1/F3 Jupiter® is an unmatched alliance between two successful instruments: the NETZSCH STA 449 F1/F3 Jupiter® and the FT-IR spectrometer by Bruker Optics. Its design is unprecedented and sets a benchmark for state-of-the-art coupling systems. Evolved Gas Analysis (EGA) is the perfect tool for characterizing the thermal behavior of organics, inorganics or polymers in more detail, elucidating the chemistry behind the processes.
PRODUCER:
PRODUCTION YEAR:
2015
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Device for determination of the elemental analysis
CATALOG NAME:
VARIO MICRO CUBE
DESCRIPTION:
Device for determination of the elemental analysis model VARIO MICRO CUBE manufacturer ELEMENTAR. Specific determinations: Range: - C: 0-7 mg (sau 100%) - N: 0-2 mg (sau 100%) - H: 0-1 mg (sau 100%) - S: 0-2 mg (sau 100%) - O: 0-6 mg (sau 100%) Accuracy:less than 0,1%
PRODUCER:
Elementar
PRODUCTION YEAR:
2010
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Total Organic Carbon Analyzer, TOC-L Shimadzu
CATALOG NAME:
TOC-LCPH/CPN PC-Controlled Model
DESCRIPTION:
Total Organic Carbon Analyzer, TOC-L Shimadzu, 680 °C Combustion Catalytic Oxidation/NDIR Detection Method.
PRODUCER:
SHIMADZU
PRODUCTION YEAR:
2012
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Calorimetry bomb
CATALOG NAME:
E2K
DESCRIPTION:
Calorimetry bomb (automated calorimeter for determination of calorific value) calorimeter model E2K MINIMUM SYSTEM for determination of calorific value of solid fuels in accordance with standard ASTM D5468- 02 and liquid fuels in accordance with the standard ASTM D240-02 and standard D4809-00.
PRODUCER:
MINIMUM SYSTEM
PRODUCTION YEAR:
2006
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Phone:
+ 4021-402 94 65
Fax:
Splaiul Independentei
,
313
,
Bucuresti
060042
,
Bucuresti - Sector 6
Romania
Loading Infrastructure
[T: 0.7886, O: 329]
Notification!
EERTIS
has replaced eeris. From now on, all updates and account activities will be on
EERTIS
. However, you can still migrate your remaining data from eeris to
EERTIS
.